Sealevel Systems VERSA COMM+4/EX Page 1
Introduction
Overview
The Sealevel Systems VERSA COMM+4/EX provides the PC with four
RS-232 asynchronous ports. The VERSA COMM+4/EX allows for connection
to any device utilizing the RS-232 electrical interface, such as modems,
data-entry terminals, and plotters.
What’s Included
The VERSA COMM+4/EX is shipped with the following items. If any of these
items is missing or damaged, contact the supplier.
• VERSA COMM+4/EX Serial I/O Adapter
• DB-37 to four DB-25 ‘Spider Cable’ (DB-9 Spider Cable is
available)
• Sealevel Software
Factory Default Settings
The VERSA COMM+4/EX factory default settings are as follows:
Port # Base Address IRQ IRQ Mode Clock Divisor
Port 1 280 5 M 4
Port 2 288 5 S 4
Port 3 290 5 S 4
Port 4 298 5 S 4
To install the VERSA COMM+4/EX using factory default settings, refer to
Installation on page 9.
For your reference, record installed VERSA COMM+4/EX settings below:
Port # Base Address IRQ IRQ Mode Clock Divisor
Port 1
Port 2
Port 3
Port 4