The “D/A Outputs” tab is useful for manually setting the digital to analog output voltages on
applicable Sealevel I/O devices with D/A channels. A preliminary diagnostics utility (see
following page) has been provided to verify proper hardware functionality.
The D/A outputs of the SeaI/O-470 are factory set for 0-10V. To configure the D/A outputs for
0-5V, you will need to open the enclosure and set the correct jumpers. Refer to the Hardware
Configuration section of this manual for instructions on opening the enclosure and accessing
the correct jumpers.
To adjust a particular channels output voltage, drag the slider until the desired voltage is
displayed in the window on the right side. Also, you may type the desired voltage directly into
the voltage display and then confirm your entry by pressing the „Enter‟ key on your keyboard.
The output voltage will not change until the „Enter‟ key is pressed or you have clicked on
the window anywhere outside of the text entry field.